WID599: DTW-121 serial communication problem. Need to check.

Posted onDecember 4, 2023December 4, 2023

Findings: 1. Always PWP panel inverter fault is showing. 2. Magnetic Contact coil damaged found. Action Taken: Magnetic contact change.

Listen to the Message WID599: DTW-121 serial communication problem. Need to check.Continue

ACTIVITY

Field Pump Checking & Maintenance.

Posted onDecember 3, 2023December 3, 2023

Checking and maintenance of 2 field pumps completed.

Listen to the Message Field Pump Checking & Maintenance.Continue

ACTIVITY

PWID57,DTW218,216,202, RTU & CCTV Panel Clening

Posted onDecember 3, 2023December 3, 2023

Listen to the Message PWID57,DTW218,216,202, RTU & CCTV Panel CleningContinue

Uncategorized

WID594: Dtw-203 Radio communication error. Need to check.

Posted onDecember 3, 2023December 3, 2023

Findings: SCADAPack STAT-LED blinking in Red signal. Action Taken: Restart the SCADAPack & radio modem.

Listen to the Message WID594: Dtw-203 Radio communication error. Need to check.Continue

ACTIVITY

DTW-218 UPS Output Voltage Showing High.

Posted onDecember 2, 2023December 2, 2023

New UPS installed at DTW-218 and old UPS brought to plant for problem checking. Now the pump is running and everything is normal.

Listen to the Message DTW-218 UPS Output Voltage Showing High.Continue

ACTIVITY

IRP#01 Main substation, Electrical Panel Room, OGR Electrical Panel Room Cleaning & Visual Check.

Posted onDecember 2, 2023December 2, 2023

IRP#01 Main substation, Electrical Panel Room, OGR Electrical Panel Room Cleaning & Visual Check Work Completed.

Listen to the Message IRP#01 Main substation, Electrical Panel Room, OGR Electrical Panel Room Cleaning & Visual Check.Continue

ACTIVITY

PWID56,DTW120,121,122, 123 RTU & CCTV Panel Clening

Posted onDecember 2, 2023December 2, 2023

Listen to the Message PWID56,DTW120,121,122, 123 RTU & CCTV Panel CleningContinue

ACTIVITY

OGR Panel Room AC Cold Air Does Not Come Out.

Posted onDecember 1, 2023December 1, 2023

AC Problem solved & Running. The functions of the remote cannot be changed. AC will automatically change after 6 hours. Everything has been…

Listen to the Message OGR Panel Room AC Cold Air Does Not Come Out.Continue

ACTIVITY

PWID55,DTW114,115,116,117,118 119 RTU & CCTV Panel Clening

Posted onNovember 29, 2023November 29, 2023

Listen to the Message PWID55,DTW114,115,116,117,118 119 RTU & CCTV Panel CleningContinue

ACTIVITY

PWID54,DTW107,109,110,111,112 111 RTU & CCTV Panel Clening

Posted onNovember 28, 2023November 29, 2023

Listen to the Message PWID54,DTW107,109,110,111,112 111 RTU & CCTV Panel CleningContinue