| 4 | 28 July 2022 | DTW205 auto start/stop problem solved | 
| 5 | 28 July 2022 | Serviced UPS install at DTW121 | 
| 6 | 28 July 2022 | Due to regeneration Boring, SCADAPack remove from dtw-202 & 104 for installing other DTW | 
| 7 | 28 July 2022 | Serviced UPS install at DTW208 | 
| 8 | 28 July 2022 | Serviced UPS install at DTW202 | 
| 9 | 30 July 2022 | DTW216 ELD Alarm Problem Clear. | 
| 10 | 30 July 2022 | DTW104 UPS Replaced | 
| 11 | 30 July 2022 | Serial Communication Problem Solved at DTW122 | 
| 12 | 01 July 2022 | OGR Booster Pump VFD cleaning done (2 Nos) | 
| 13 | 02 July 2022 | IRP-2 Sand Filter Blower VFD cleaning | 
|  | 02 July 2022 | MOV-3V07D logic card change & reprogram. | 
| 14 | 03 July 2022 | DTW-115 & 119 VFD,RTU & LV panel cleaning. | 
| 15 | 04 July 2022 | DTW- 114 & 118 VFD,RTU & LV panel cleaning. | 
| 16 | 05 July 2022 | IRP-1 NAV Cleaning and maintenance. | 
| 17 | 07 July 2022 | LIT install at DTW-220 | 
| 18 | 07 July 2022 | 1 Nos Camera remove from DTW-103 | 
| 19 | 09 July 2022 | Dtw-205 serial comm. cable connection tightness check. | 
| 20 | 10 July 2022 | IRP-2 inlet FIT-3001 sensor maintenance. | 
| 21 | 11 July 2022 | DTW-207 GI-MAC power meter resetting to solve the problem. | 
| 22 | 13 July 2022 to 16 July 2022 | Fiber Optic cable maintenance from DTW- 113 to 123. | 
| 23 | 14 July 2022 | Find out the problem of IRP-1 Utility Pump | 
| 24 | 17 July 2022 | IRP-1 CCTV server panel and SCADA room 2Nos printer cleaning. | 
| 25 | 17 July 2022 | DTW- 120,121 & 123 VFD,RTU & LV panel cleaning. | 
| 26 | 17 July 2022 | DTW- 120 Pump terminal loose connection find out tightening. | 
| 27 | 18 July 2022 | DTW- 122 frequency regulator tested for serial comm. errror. | 
| 28 | 18 July 2022 | DTW- 212 CCTV PoE switch problem identify. | 
| 29 | 18 July 2022 | DTW- 212 CCTV  new PoE switch install. | 
|  | 18 July 2022 | IRP-2 CCTV server panel and SCADA room Cleaning | 
| 30 | 19 July 2022 | DTW-120 Pump current, Hz & PIT value check. | 
| 31 | 24 July 2022 | DTW- 110 & 111 VFD,RTU & LV panel cleaning. | 
| 32 | 25 July 2022 | DTW-118 new CAT-6 cable install for serial comm. | 
| 33 | 25 July 2022 | Serviced UPS install at DTW-101. | 
| 34 | 26 July 2022 | Serviced UPS install at DTW-105. | 
| 35 | 27 July 2022 | Serviced UPS install at DTW-120 | 
| 36 | 27 July 2022 | DTW-118 RS-485 cable connection. | 
| 37 | 28 July 2022 | DTW- 205 start/stop problem solved. | 
| 38 | 28 July 2022 | Serviced UPS install at DTW-202. | 
| 39 | 28 July 2022 | Serviced UPS install at DTW-208. | 
| 40 | 28 July 2022 | Serviced UPS install at DTW-121. | 
| 41 | 29 July 2022 | Due to degeneration of boring , SCADAPack remove from DTW- 104 & 202. | 
| 42 | 30 July 2022 | DTW-216 ELD alarm is showing . Field check complete. | 
| 43 | 30 July 2022 | Serviced UPS install at DTW-104. | 
| 44 | 30 July 2022 | DTW-122 Modbus interrupt problem solved. | 
| 45 | 31 July 2022 | 3 Nos CCTV maintenance & repairing. | 
| 46 | 31 July 2022 | Serviced UPS install at DTW-119. | 
|  |  |  | 
|  |  |  | 
|  |  |  | 
|  |  |  | 
|  |  |  |